| Type | B type controller | E type controller | G type controller | ||
| Motor control voltage | AC220V/50Hz | ||||
| Aux. Power | / | DC 24V | GA Type | GB Type | GC Type |
| 1, DC 12V 2, DC 24V |
Passive Output | AC 220V | |||
| Voltage Measuring Range | AC 40 to 300V | ||||
| Power Loss | less or equal 10W | ||||
| Working Position | (Normal power ON, Reserve power ON, OFF) Three working position | Three (I power ON, II power ON, I/II power OFF) | |||
| Operating Mode | Auto, Manual | Auto, Manual, Remote | Auto, Manual | ||
| Display Mode | LED Indicator | LCD Display | LED Indicator | ||
| Runing Status LED Indicators | I/II POWER; I/II ON | ||||
| Voltage Display | No | Yes | No | ||
| Transfer Mode | Auto Transfer and Recovery | Auto Transfer auto recovery / Auto transfer no recovery | Auto Transfer and Recovery | ||
| Source Priority | Default no source priority | Settable I/II/No Priority | Default no source priority | ||
| Under voltage transfer value | NO | +/- 20% Adjustable | NO | ||
| Over voltage transfer value | NO | +/- 20% Adjustable | NO | ||
| Transfer Delay Function | NO | 0~180s Adjustable | NO | ||
| Recovery Delay Function | NO | 0~180s Adjustable | NO | ||
| Phase missing detect | Single phase (A Phase) | Three phase (A,B,C Phase) | Single phase (A Phase) | ||
| Generator control | Yes (one set DC2A relay contact) | ||||
| Fire-linkage control | Yes (passive contact input, with one set NO passive feedback signal) | ||||
| RS485 function | NO | Yes | NO | ||
| Frequency Protection | NO | +/-20% adjust | NO | ||
| Engine Exerciser | NO | Yes | NO | ||
| ATS Features Comparing, RDS2 -- Outdated type ATS | ||
| RDS2 | Outdated type ATS | |
![]() |
![]() |
|
| Certificates | CE, RoHS | / |
| Flame-retardant Cover | Yes | No |
| Working voltage (L-N) | Wide(150VAC-300VAC) | Ordinary |
| Controller | Intelligent and settable | Simple, fixed function |
| I Power LED Indicator | Yes | No |
| II Power LED Indicator | Yes | No |
| I Power ON LED Indicator | Yes | No |
| II Power ON LED Indicator | Yes | No |
| Over/Under Voltage Protection | Yes | No |
| Over/Under Frequency Protection | Yes | No |
| Transfer Time Delay | Settable | Fixed |
| Generator Start/Stop Time Delay | Settable | No |
| Engine Exciser(weekly, monthly etc.) | Yes | No |
| Phase Immbalance Protection | Yes (custom made) | No |
| Size | Compact | Larger |
| Copper Bar | 2 Input 1 Output | 2 Input 2 Output(some) |
| Operation Handle | Iron(solid) | Plastic(crispy) |
| Fuse | Yes | No |
| Outlook | Distinguished & Elegant | Common |
| Motor Brand | CNDF | Wuxi, inferior quality |
| Before Factory Testing | Auto Testing Line/Manual | Manual check |