Sp1-C 230/400V 20ka SPD for Power Supply System

  • Audited Supplier
  • 11 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Zinc Oxide Arrester Structure: Equipped with heavy duty zinc oxide varistor for effective surge protection.
  • Multi-Pole Configuration: Available in 1P, 1P+N, 2P, 3P, 3P+N, and 4P options for diverse systems.
  • Certified Quality Standards: Complies with ISO9001 and CCC certifications for reliable performance.
  • Flexible Operating Voltage: Designed for AC 50/60Hz, 230/400V systems with Uc ranging from 275V to 460V.
  • Remote Signal Output Option: Optional auxiliary function for remote alarm and status monitoring.
  • Adaptable to Multiple Earthing Systems: Suitable for TT, IT, TN-S, and TN-C-S power supply systems.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Sp1-C 230/400V 20ka SPD for Power Supply System

Sp1-C 230/400V 20ka SPD for Power Supply System
Sp1-C 230/400V 20ka SPD for Power Supply System pictures & photos
Sp1-C 230/400V 20ka SPD for Power Supply System
Sp1-C 230/400V 20ka SPD for Power Supply System pictures & photos
Sp1-C 230/400V 20ka SPD for Power Supply System
Sp1-C 230/400V 20ka SPD for Power Supply System pictures & photos
Sp1-C 230/400V 20ka SPD for Power Supply System
  • Sp1-C 230/400V 20ka SPD for Power Supply System
  • Sp1-C 230/400V 20ka SPD for Power Supply System
    Sp1-C 230/400V 20ka SPD for Power Supply System
  • Sp1-C 230/400V 20ka SPD for Power Supply System
    Sp1-C 230/400V 20ka SPD for Power Supply System
  • Sp1-C 230/400V 20ka SPD for Power Supply System
    Sp1-C 230/400V 20ka SPD for Power Supply System

Find Similar Products

Product Description

Sp1-C 230/400V 20ka SPD for Power Supply System

Surge Protection Device (SPD)

 
It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.
 
SPD for Power Supply System Series Selection Guide
 
  The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
  The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose. 
  SPD for power supply system specification selection principle 
  Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage. 
  TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
  TN System: Uc≥1.15Uo
  IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
  Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
  Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
 
SP1 Series
 
Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
        Normal range: -5ºC~+40ºC
        Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust) 
 
Classification
 
-As per Nominal Discharge Current: 
    5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage: 
    275V,320V,385V,420V,440V,460V
- As per to poles
   1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
    a. With remote signal output ( remote alarm function)
    b. Without remote signal output
 
Selection Principle
 
- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

SP1-C (Class II Protection)

 
Application
  SP1-C series SPD is suitable for TT,IT,TN-S,TN-C-S power supply system with AC 50/60Hz,230/400V and below. Its design based on IEC6143-1, GB18802.1 and GB50057 standard requirements. Mainly used for protect the low voltage electrical device to prevent the surge current caused by air discharge (such as lightning) or operating over voltage, used as one kind of voltage limiting device, it equipped with heavy duty zinc oxide varistor.
  SP1-C type SPD should installed as near as possible to the upstream line side of the protected equipment (immediately connect to the downstream of incoming line), as earthing device to connecting external conductor (L) or neutral line and user equipment. Installed at transition area of LPZOA/OB and LPZ1 zone or LPZ1 and LPZ2 zone, normally installed at the incoming of low voltage main distribution board.
Sp1-C 230/400V 20ka SPD for Power Supply SystemSp1-C 230/400V 20ka SPD for Power Supply System
 
 
Sp1-C 230/400V 20ka SPD for Power Supply System
 
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2631331". Items marked "verified" are certified.

Watch Video
Watch Video
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.

About Our Factory & Business Background

Address
No. 55, South Pu Fifth Road, Yueqing Economic Development Zone, Yueqing City, Wenzhou City, Zhejiang Province, P. R. China
Terms of Payment
LC, T/T, D/P, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW, Others
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI, WENZHOU

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Switches, Changeover Switches, Load Break Switches, Control & Protective Switches, Varied Frequency Switchwes, Circuit Breakers, Transfer Switches, Timers and Control Relays, Power Meters, LED Indicators

Our Industry Experience & Global Business Record

Export Year
2016-01-22
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Which power supply systems are compatible?
It is suitable for TT, IT, TN-S, and TN-C-S power supply systems with AC 50/60Hz and voltage up to 230/400V.
What are the installation distance requirements?
The distance between each level of SPD should not exceed 10m, and the distance to protected equipment should be as short as possible, ideally under 10m.
What certifications does the product have?
The product holds ISO9001 and CCC certifications, ensuring compliance with international and local quality standards.
Can the product provide remote monitoring?
Yes, an optional auxiliary function allows for remote signal output, enabling remote alarm and status monitoring.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now