Product Highlights

  • Comprehensive Protection: Protects motors from open-phase, phase sequence errors, voltage imbalance, and over/under voltage.
  • Adjustable Voltage Settings: HHD10-D model features panel-adjustable over/under voltage thresholds and delay times.
  • Wide Voltage Tolerance: Works with 380V AC 50Hz power supply, allowing 85% to 110% voltage fluctuations.
  • DIN-Rail Installation: Designed for direct installation on DIN-rails for easy integration into control cabinets.
  • High Electrical Life: Rated for 100,000 electrical switching cycles for long-term reliable operation.
  • Robust Contact Capacity: Supports 3A AC250V resistive load capacity for effective motor control circuit switching.
  • Flexible Delay Options: Offers adjustable delay times from 0.5s to 10s depending on the specific protection mode.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays

Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays pictures & photos
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays pictures & photos
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays pictures & photos
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays pictures & photos
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
  • Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
  • Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
    Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
  • Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
    Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
  • Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
    Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
  • Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
    Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays

Find Similar Products

Product Description

Open-phase, phase sequence, Three-phase unbalance and Over/under voltage protection relays
Product Description

Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays


Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays
Phase Loss Failure Sequence Three-Phase Unbalance and Over/Under Voltage Protection Relays


Application


HHD11 series open-phase, phase sequence, Three-phase unbalance and Over/under voltage protection relay (hereinafter abbr. protection relay) is apply for AC 50Hz, 380V motor control circuitry which compose of AC contactor and other switching devices. When the motor's main circuit is on abnormal state, eg. out of phase, phase failure, voltage imbalance, etc. the protection relay will disconnect the switch contact and motor's three-phase power supply, so as to protection of the motor timely.

Main Technical Data
1, Working power: Three-phase 380V 50Hz, (85% to 110%) Ue fluctuations allowed.
2, Open-phase protection: Protection relay adopts sampling voltage (R, S, T front part ) and action when it detects any phase failure.
3, Phase sequence protection: When protection relay phase sequence is confirmed, if any phase line is exchanged, the motor will not start.
4, Voltage imbalance protection: for three-phase power supply, when any two-phase voltage imbalance comes to 50V ~ 75V, protection relay will act and protect the motor.
5, HHD10-C overvoltage protection: 445V ~ 465V not adjustable, delay 3s ~ 5s not adjustable; HHD10-D over-voltage protection: 400V ~ 460V (panel adjustable), delay 0.5s ~ 5s (panel adjustable) The
6, HHD10-C undervoltage protection: 290V ~ 310V is not adjustable, action delay time 3s ~ 5s not adjustable, HHD10-D over-voltage protection; 300V ~ 360V (adjustable at panel), action delay time 1s ~ 10s (adjustable at panel).
7, Open-phase protection action time 3s ~ 5s.
8, Phase sequence protection action time ≤ 0.2s.
9, Contact capacity: 3A AC250V (resistive).
10, Electrical life: 1×105 times.
11, Ambient temperature: -5 ºC ~ 40 ºC.
12, Alititude: ≤ 2000m.
13, Humidity: When the installation site's max. temperature is 40 ºC, the relative humidity ≤ 50%, it can allow a higher relative humidity at lower temperatures. eg. 20 ºC up to 90%. Special measures should be taken for occasional condensation due to temperature changes.
14, Installation: direct install, by DIN-rail.
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2631331". Items marked "verified" are certified.

Watch Video
Watch Video
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.

About Our Factory & Business Background

Address
No. 55, South Pu Fifth Road, Yueqing Economic Development Zone, Yueqing City, Wenzhou City, Zhejiang Province, P. R. China
Terms of Payment
LC, T/T, D/P, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW, Others
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI, WENZHOU

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Switches, Changeover Switches, Load Break Switches, Control & Protective Switches, Varied Frequency Switchwes, Circuit Breakers, Transfer Switches, Timers and Control Relays, Power Meters, LED Indicators

Our Industry Experience & Global Business Record

Export Year
2016-01-22
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What protections does the HHD11 series relay provide?
It provides protection against open-phase, phase sequence errors, three-phase voltage imbalance, and over/under voltage conditions.
What is the working power supply requirement?
The relay requires a three-phase 380V 50Hz power supply, allowing for voltage fluctuations between 85% and 110% of the rated voltage.
Is the over/under voltage protection adjustable?
The HHD10-D model allows panel adjustment for both voltage thresholds (400V-460V over, 300V-360V under) and delay times. The HHD10-C model is fixed.
How does the phase sequence protection work?
If any phase line is exchanged, the relay confirms the incorrect sequence and prevents the motor from starting to avoid damage.
What is the action time for phase sequence protection?
The phase sequence protection acts very quickly, with an action time of less than or equal to 0.2 seconds.
What are the installation requirements?
The relay is designed for direct installation using a standard DIN-rail mounting method.
What is the electrical life of the relay?
The relay has an electrical life of 100,000 switching cycles.
What is the contact capacity of the relay?
The contact capacity is rated at 3A AC250V for resistive loads.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now