Product Highlights

  • High Surge Capacity: Discharges up to 100kA lightning overcurrent with max 60kA protection.
  • Fast Response Time: Response time is less than 25ms for immediate surge protection.
  • Modular Hot-Plug Design: Stable integrated base allows easy replacement without power interruption.
  • Visual Status Indication: Color window shows status: Green for normal, Red for fault.
  • Wide Voltage Compatibility: Suitable for 230/400V AC/DC systems including TT, IT, TN-S, TN-C.
  • Standard DIN Rail Mount: Fits 35mm DIN rail, matching most general installation requirements.
  • High Flame Resistance: Case material PBT/PA66 meets V0 flame class standard.
  • Multiple Pole Options: Available in 1P, 2P, 1P+N, 3P, 4P, and 3P+N configurations.

Product Images of Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD

Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD pictures & photos
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD pictures & photos
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD pictures & photos
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD pictures & photos
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD pictures & photos
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD pictures & photos
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
    Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
    Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
    Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
    Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
    Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
  • Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
    Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD

Find Similar Products

Product Description

Introduction
SP5 series surge protection devices are suitable for all levels of lightning protection areas under AC 50/60Hz, 230/400V TT, IT, TN-S, TN-C, TN-CS and other power supply systems, and can discharge up to 100KA lightning overcurrent.
Installation should be installed as close as possible to the upstream line end of the protected equipment, and connect the outer conductor (L) or neutral line (N) to the grounding device of the customer's equipment. If the installation distance cannot be guaranteed, additional installations are required between all levels of protectors. Decoupling components, adding an inductor in low-voltage power supply system can achieve the purpose of decoupling.

Product Features
  1. New designed cases;
  2. Low residual voltage of impulse current, high withstand capacity;
  3. Fast response time less than 25ms;
  4. Stable integrated base, modular design with hot-plug;
  5. Indication window color shows SPD status; (Green for normal, red for fault)
  6. 35mm Rail mounting, match most general installation requirements.
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPDApplication
For civil application

Sp5-60 Lightning Arrester Max 60ka Surge Protection SPD
For industrial application
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPDTechnical Data
Item SP5-10 SP5-20 SP5-40 SP5-60 SP5-80
Nominal discharge current  In(8/20us) 5KA 10KA 20KA 30KA 40KA
Max discharge current  In(8/20us) 10KA 20KA 40KA 60KA 80KA
Max. continuous operating voltage  Uc (V) 270 320 385 420 270 320 385 460 270 320 385 460 270 320 385 460 270 320 385 460
Varistor voltage  U1mA (V) 430 510 620 680 430 510 620 710 430 510 620 710 430 510 620 710 430 510 620 710
Protection level      Up (kA) 1.0 1.2 1.2 1.2 1.0 1.4 1.6 1.8 1.2 1.6 1.8 2.0 1.5 1.8 2.0 2.2 1.6 1.8 2.2 2.3
Poles 1P, 2P, 1P+N, 3P, 4P, 3P+N
Rated working voltage   Un(V) 230/400
Response time (ms) ≤25
Test classification Class II
IP protection class IP20
Flame class V0
Case material PBT/PA66
Recommended fuse or circuit breaker (A) 40∽60
Installation method 35mm DIN rail mounting
Standards GB/T 18802.11    IEC61643-11
Sp5-60 Lightning Arrester Max 60ka Surge Protection SPDSp5-60 Lightning Arrester Max 60ka Surge Protection SPDSp5-60 Lightning Arrester Max 60ka Surge Protection SPD

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2631331". Items marked "verified" are certified.

Watch Video
Watch Video
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.
Radin Electric Technology Co., Ltd.

About Our Factory & Business Background

Address
No. 55, South Pu Fifth Road, Yueqing Economic Development Zone, Yueqing City, Wenzhou City, Zhejiang Province, P. R. China
Terms of Payment
LC, T/T, D/P, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW, Others
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI, WENZHOU

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Switches, Changeover Switches, Load Break Switches, Control & Protective Switches, Varied Frequency Switchwes, Circuit Breakers, Transfer Switches, Timers and Control Relays, Power Meters, LED Indicators

Our Industry Experience & Global Business Record

Export Year
2016-01-22
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum discharge current?
The device can discharge up to 100kA lightning overcurrent, with specific models offering max discharge currents ranging from 10kA to 80kA.
How fast is the response time?
The response time is less than 25ms, ensuring rapid protection against surges.
What installation method is required?
It uses 35mm DIN rail mounting and should be installed as close as possible to the upstream line end of the protected equipment.
How can I check the device status?
An indication window shows the status: Green indicates normal operation, while Red indicates a fault.
What are the available pole configurations?
Available poles include 1P, 2P, 1P+N, 3P, 4P, and 3P+N to suit various system needs.
Is the device suitable for industrial use?
Yes, it is designed for both civil and industrial applications under AC 50/60Hz power supply systems.
What standards does the product meet?
The product complies with GB/T 18802.11 and IEC61643-11 standards.
What is the lead time for orders?
Peak season lead time is one month, while off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now