Automatic Changeover with Current Limiter Accl Single Phase

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Warranty: 2 Year
Brand: Radin
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Address
No. 319, Wei 18th Road, Yueqing Economic Development Zone, Wenzhou, Zhejiang, China
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW, Others
Terms of Payment
LC, T/T, D/P, Western Union, Money Gram
  • Automatic Changeover with Current Limiter Accl Single Phase
  • Automatic Changeover with Current Limiter Accl Single Phase
  • Automatic Changeover with Current Limiter Accl Single Phase
  • Automatic Changeover with Current Limiter Accl Single Phase
  • Automatic Changeover with Current Limiter Accl Single Phase
Find Similar Products

Basic Info.

Model NO.
ACCL-R300
Operation
Electric
Certification
CCC, CE, ISO9001
Type
Integrated automatic transfer switch
Poles
3p/4p
Output type
Dual
Rated Current
30A
Frequency
50/60Hz
Voltage
230V
Color
White or Black
Transport Package
Carton Box
Specification
CCC, CE
Trademark
RADIN
Origin
Zhejiang, China
HS Code
8536500000
Production Capacity
1000 PCS/Month

Product Description

Micro-processor based Automatic changeover 
Overload current limit protection for Generator 
Over/under voltage protection for Generator
Programmable re-close cycles after overload trip
Reset option available after trip locked

Introduction

 ACCL-R300 Series automatic Changeover with Current Limiter is mainly used for household or light industrial to protect the generator from overload and over/under voltage conditions.

 

   ACCL is recommended for neccessary loads like tube-lights, fans, computer, TV etc, and connect heavy loads such as motors directly on the Mains EB.

  Only ACCL is powered by generator, then it start monitoring Mains&Genset supply. If load on Mains and Mains fail then ACCL will automatically changeover the load to Genset after a preset time delay.

  When Mains resumes, ACCL shift load to Mains after a preset time delay, but if mains resumes and Genset switch OFF immediately then load gets transferred to Mains immediately.

  In case of Overload condition on Genset:

  When OVERLOAD happens and load on Genset side, ACCL will disconnect supply to load and the TRIP light will be ON as warning.

   ACCL will re-connect the load after 1st re-close time delay to check the overload condition, if overload still exist during 2min, ACCL will disconnect supply to load again, ACCL in trip statues. 

   ACCL will repeat re-close cycles for preset re-close cycles ( default 5 cycles), after OVERLOAD still happens after pre-set cycles, then ACCL will disconnect the load supply and lock in disconnect status.

  To restore the supply:

  a): Switch OFF the non-essential load

  b): Press RESET button on ACCL to resume normal working

Product Introduction

Automatic Changeover with Current Limiter Accl Single Phase

Recommend Wiring Connection
Automatic Changeover with Current Limiter Accl Single Phase

 

Overall Dimensions

Automatic Changeover with Current Limiter Accl Single Phase

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now